AD 2013-11-17
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Embraer S.A. | ERJ 170-100 LR | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 170-100 SE | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 170-100 STD | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 170-100 SU | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 170-200 LR | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 170-200 STD | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 170-200 SU | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-100 ECJ | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-100 IGW | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-100 LR | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-100 STD | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-200 IGW | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-200 LR | Airworthiness Directives; Embraer S.A. Airplanes |
| aircraft | Embraer S.A. | ERJ 190-200 STD | Airworthiness Directives; Embraer S.A. Airplanes |
Unsafe Condition
The possibility of a dual engine in-flight shutdown due to LPCV failure.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the low-stage check valve and associated seals of the right hand (RH) engine's engine bleed system with a new check valve and new seals. Replace the low pressure check valves (LPCVs). Replace certain LPCVs of the left hand (LH) and RH engines. Revise the maintenance program.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Embraer S.A. Model ERJ 170 and ERJ 190 airplanes, specifically certain configurations including ERJ 170-100 LR, -100 STD, -100 SE, -100 SU, -200 LR, -200 STD, and -200 SU.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
We are superseding airworthiness directive (AD) 2010-14-14 that applies to certain Embraer S.A. Model ERJ 170 and ERJ 190 airplanes. AD 2010-14-14 currently requires, for certain airplanes, repetitively replacing the low-stage check valve and associated seals of the right hand (RH) engine's engine bleed system with a new check valve and new seals, replacing the low pressure check valves (LPCVs), and revising the maintenance program. For certain other airplanes, AD 2010-14-14 requires replacing a certain low-stage check valve with an improved low-stage check valve. For certain airplanes, this new AD adds replacing certain LPCVs of the left hand (LH) and RH engines, which would be an option for other airplanes. This AD was prompted by reports of uncommanded engine shutdowns on both Model ERJ 170 and ERJ 190 airplanes due to excessive wear and failure of LPCVs having certain part numbers. We are issuing this AD to prevent the possibility of a dual engine in-flight shutdown due to LPCV failure.
Applicability Source Text
Show captured applicability text from the source AD
(c) Applicability
This AD applies to Embraer S.A. Model ERJ 170-100 LR, -100 STD,
-100 SE., and -100 SU airplanes; Model ERJ 170-200 LR, -200 SU, and
-200 STD airplanes; Model ERJ 190-100 STD, -100 LR, -100 ECJ, and -
100 IGW airplanes; and Model ERJ 190-200 STD, -200 LR, and -200 IGW
airplanes; certificated in any category; having Hamilton Sundstrand
low pressure check valve (LPCV) part number (P/N) 1001447-3 or
1001447-4.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 78, Number 127 (Tuesday, July 2, 2013)]
[Rules and Regulations]
[Pages 39567-39571]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 2013-15637]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2012-1230; Directorate Identifier 2011-NM-107-AD;
Amendment 39-17477; AD 2013-11-17]
RIN 2120-AA64
Airworthiness Directives; Embraer S.A. Airplanes
AGENCY: Federal Aviation Administration (FAA), Department of
Transportation (DOT).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are superseding airworthiness directive (AD) 2010-14-14
that applies to certain Embraer S.A. Model ERJ 170 and ERJ 190
airplanes. AD 2010-14-14 currently requires, for certain airplanes,
repetitively replacing the low-stage check valve and associated seals
of the right hand (RH) engine's engine bleed system with a new check
valve and new seals, replacing the low pressure check valves (LPCVs),
and revising the maintenance program. For certain other airplanes, AD
2010-14-14 requires replacing a certain low-stage check valve with an
improved low-stage check valve. For certain airplanes, this new AD adds
replacing certain LPCVs of the left hand (LH) and RH engines, which
would be an option for other airplanes. This AD was prompted by reports
of uncommanded engine shutdowns on both Model ERJ 170 and ERJ 190
airplanes due to excessive wear and failure of LPCVs having certain
part numbers. We are issuing this AD to prevent the possibility of a
dual engine in-flight shutdown due to LPCV failure.
DATES: This AD becomes effective August 6, 2013.
The Director of the Federal Register approved the incorporation by
reference of certain publications listed in this AD as of August 6,
2013.
The Director of the Federal Register approved the incorporation by
reference of certain other publications listed in this AD as of August
26, 2010 (75 FR 42585, July 22, 2010).
The Director of the Federal Register approved the incorporation by
reference of a certain publication listed in this AD as of September
13, 2007 (72 FR 44734, August 9, 2007).
The Director of the Federal Register approved the incorporation by
reference of a certain other publication listed in this AD as of
November 29, 2005 (70 FR 69075, November 14, 2005).
ADDRESSES: You may examine the AD docket on the Internet at <a href="http://www.regulations.gov">http://www.regulations.gov</a> or in person at the U.S. Department of
Transportation, Docket Operations, M-30, West Building Ground Floor,
Room W12-140, 1200 New Jersey Avenue SE., Washington, DC.
FOR FURTHER INFORMATION CONTACT: Cindy Ashforth, Aerospace Engineer,
International Branch, ANM-116, Transport Airplane Directorate, FAA,
1601 Lind Avenue SW., Renton, WA 98057-3356; telephone (425) 227-2768;
fax (425) 227-1149.
SUPPLEMENTARY INFORMATION:
Discussion
We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR
part 39 to include an AD that would apply to the specified products.
The NPRM was published in the Federal Register on December 26, 2012 (77
FR 75911), and proposed to supersede AD 2010-14-14, Amendment 39-16359
(75 FR 42585, July 22, 2010). (AD 2010-14-14 superseded AD 2007-16-09,
Amendment 39-15148 (72 FR 44734, August 9, 2007)). AD 2007-16-09
superseded AD 2005-23-14, Amendment 39-14372 (70 FR 69075, November 14,
2005). The NPRM proposed to correct an unsafe condition for the
specified products. The Mandatory Continuing Airworthiness Information
(MCAI) for Embraer S.A. Model ERJ 170 airplanes states:
It has been found the occurrence of an engine in-flight shutdown
* * * caused by the LPCV failure P/N [part number] 1001447-3 with
3,900 Flight Hours (FH) installed on ERJ-170. This valve failed [to]
open due [to] excessive wear. [I]t was found the occurrence of an
engine shutdown on-ground, caused by the LPCV failure P/N 1001447-4
with 1,802 FH installed on ERJ-190 failed due [to] low cycle
fatigue. Since the behavior of a valve P/N 1001447-4 removed from
ERJ-190 is unknown on ERJ-170 and the P/N 1001447-4 is common
between ERJ-170 and ERJ-190 airplane fleet, an action is necessary
to prevent the installation, in ERJ-170 airplanes, of LPCVs P/N
1001447-4 previously installed in ERJ-190 airplanes.
* * * * * * *
The MCAI for Embraer S.A. Model ERJ 190 airplanes states:
It has been found the occurrence of an engine in-flight shutdown
* * * caused by the LPCV failure P/N 1001447-3 with 3,900 Flight
Hours (FH) installed on ERJ-170. This valve failed [to] open due
[to] excessive wear. [I]t was found the occurrence of an engine
shutdown on-ground, caused by the LPCV failure P/N 1001447-4 with
1,802 FH installed on ERJ-190 failed due [to] low cycle fatigue.
Since the behavior of a valve P/N 1001447-4 removed from ERJ-170 is
unknown on ERJ-190 and the P/N 1001447-4 is common between ERJ-170
and ERJ-190 airplane fleet, an action is necessary to prevent the
installation, in ERJ-190 airplanes, of LPCVs P/N 1001447-4
previously installed in ERJ-170 airplanes.
* * * * *
The unsafe condition is the possibility of a dual engine in-flight
shutdown due to LPCV failure. The required actions include the actions
required by AD 2010-14-14, Amendment 39-16359 (75 FR 42585, July 22,
2010), and, for certain airplanes, replacing the LPCVs of the LH and RH
engines, which would be an option for certain other airplanes. You may
obtain further information by examining the MCAI in the AD docket.
Comments
We gave the public the opportunity to participate in developing
this AD. We have considered the comment received.
Request for Clarification of Approved Method
US Airways requested clarification of paragraph (l) of the NPRM (77
FR 75911, December 26, 2012), which requires installing a new LPCV
using a method approved by either the Manager, International Branch,
ANM-116, Transport Airplane Directorate, FAA; or Ag[ecirc]ncia Nacional
de Avia[ccedil][atilde]o Civil (ANAC) (or its delegated agent). The
commenter requested clarification of the approved method so operators
can understand acceptable and unacceptable methods of installation. The
commenter also stated that the approved method needs to be stated to
avoid having to obtain approval of an alternative method of compliance
(AMOC) allowing use of certain documents.
We agree to provide clarification. We have reviewed EMBRAER Service
Bulletins 190-36-0014, Revision 01, dated January 14, 2009; 190-LIN-36-
0004, dated December 23, 2009; and 170-36-0011, Revision 2, dated July
19, 2007. Those bulletins provide instructions for installing P/N
1001447-
[[Page 39568]]
4; however, they may be used to install P/N 1001447-6. We have added
paragraphs (l)(2) and (m)(2) to this AD to provide references for
installing P/N 1001447-6. We have also added note 1 to paragraph (n) of
this AD to provide guidance for an optional terminating action. Embraer
has not published installation instructions specifically for the P/N
1001447-6 that can be incorporated by reference in this AD. We will
consider approving any alternate installation instructions that
operators propose.
Clarification of Calculation for Equivalent Flight Hours
We have revised paragraph (k)(4)(ii) of this AD to clarify the
calculation for equivalent flight hours.
Conclusion
We reviewed the available data, including the comment received, and
determined that air safety and the public interest require adopting the
AD as proposed except for minor editorial changes. We have determined
that these minor changes:
<bullet> Are consistent with the intent that was proposed in the
NPRM (77 FR 75911, December 26, 2012) for correcting the unsafe
condition; and
<bullet> Do not add any additional burden upon the public than was
already proposed in the NPRM (77 FR 75911, December 26, 2012).
Costs of Compliance
We estimate that this AD will affect about 253 products of U.S.
registry.
We estimate the following costs to comply with this proposed AD:
Estimated costs
----------------------------------------------------------------------------------------------------------------
Number of U.S.-
Action Labor cost Cost per product registered Cost on U.S.
airplanes operators
----------------------------------------------------------------------------------------------------------------
Replacement of RH check valves on 3 work-hours x $85 $255 per 55 $14,025 per
Model ERJ 170-100 LR, -100 STD, - per hour = $255 replacement cycle. replacement cycle.
100 SE, and -100 SU airplanes per replacement
(retained actions from AD 2010- cycle.
14-14 (75 FR 42585, July 22,
2010)).
Replacement of LH check valves on 3 work-hours x $85 $255 per 75 $19,125 per
Model ERJ 170-100 LR, -100 STD, - per hour = $255 replacement cycle. replacement cycle.
100 SE, -100 SU, -200 LR, -200 per replacement
STD, and -200 SU airplanes cycle.
(retained actions from AD 2010-
14-14 (75 FR 42585, July 22,
2010)).
Replacement of LPCVs with P/N 2 work-hours x $85 $170............... 253 $43,010.
1001447-6 (new action). per hour = $170.
Revision of maintenance program 1 work-hour x $85 $85................ 253 $21,505.
(new action). per hour = $85.
----------------------------------------------------------------------------------------------------------------
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, section 106, describes the
authority of the FAA Administrator. ``Subtitle VII: Aviation
Programs,'' describes in more detail the scope of the Agency's
authority.
We are issuing this rulemaking under the authority described in
``Subtitle VII, Part A, Subpart III, Section 44701: General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
We determined that this AD will not have federalism implications
under Executive Order 13132. This AD will not have a substantial direct
effect on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
1. Is not a ``significant regulatory action'' under Executive Order
12866;
2. Is not a ``significant rule'' under the DOT Regulatory Policies
and Procedures (44 FR 11034, February 26, 1979);
3. Will not affect intrastate aviation in Alaska; and
4. Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
We prepared a regulatory evaluation of the estimated costs to
comply with this AD and placed it in the AD docket.
Examining the AD Docket
You may examine the AD docket on the Internet at <a href="http://www.regulations.gov">http://www.regulations.gov</a>; or in person at the Docket Operations office
between 9 a.m. and 5 p.m., Monday through Friday, except Federal
holidays. The AD docket contains the NPRM (77 FR 75911, December 26,
2012), the regulatory evaluation, any comments received, and other
information. The street address for the Docket Operations office
(telephone (800) 647-5527) is in the ADDRESSES section.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by removing airworthiness directive (AD)
2010-14-14, Amendment 39-16359 (75 FR 42585, July 22, 2010), and adding
the following new AD:
2013-11-17 Embraer S.A.: Amendment 39-17477. Docket No. FAA-2012-
1230; Directorate Identifier 2011-NM-107-AD.
(a) Effective Date
This airworthiness directive (AD) becomes effective August 6,
2013.
[[Page 39569]]
(b) Affected ADs
This AD supersedes AD 2010-14-14, Amendment 39-16359 (75 FR
42585, July 22, 2010).
(c) Applicability
This AD applies to Embraer S.A. Model ERJ 170-100 LR, -100 STD,
-100 SE., and -100 SU airplanes; Model ERJ 170-200 LR, -200 SU, and
-200 STD airplanes; Model ERJ 190-100 STD, -100 LR, -100 ECJ, and -
100 IGW airplanes; and Model ERJ 190-200 STD, -200 LR, and -200 IGW
airplanes; certificated in any category; having Hamilton Sundstrand
low pressure check valve (LPCV) part number (P/N) 1001447-3 or
1001447-4.
(d) Subject
Air Transport Association (ATA) of America Code 36, Pneumatic.
(e) Reason
This AD was prompted by reports of uncommanded engine shutdowns
on both Model ERJ 170 and ERJ 190 airplanes due to excessive wear
and failure of LPCVs having certain part numbers. We are issuing
this AD to prevent the possibility of a dual engine in-flight
shutdown due to LPCV failure.
(f) Compliance
You are responsible for having the actions required by this AD
performed within the compliance times specified, unless the actions
have already been done.
(g) Retained Replacement for Right-Hand (RH) Engine on Model ERJ 170-
100 LR, -100 STD, -100 SE., and -100 SU Airplanes
This paragraph restates the requirements of paragraph (f) of AD
2010-14-14, Amendment 39-16359 (75 FR 42585, July 22, 2010). For
Model ERJ 170-100 LR, -100 STD, -100 SE., and -100 SU airplanes
equipped with LPCVs having P/N 1001447-3: Within 100 flight hours
after November 29, 2005 (the effective date of AD 2005-23-14,
Amendment 39-14372 (70 FR 69075, November 14, 2005)), or prior to
the accumulation of 3,000 total flight hours, whichever occurs
later, replace the low-stage check valve and associated seals of the
RH engine's engine bleed system with a new check valve and new
seals, in accordance with the Accomplishment Instructions of EMBRAER
Alert Service Bulletin 170-36-A004, dated September 28, 2005; or
paragraph 3.C. of the Accomplishment Instructions of EMBRAER Service
Bulletin 170-36-0004, dated November 18, 2005, or Revision 01, dated
March 10, 2008. As of August 26, 2010 (the effective date of AD
2010-14-14), only use EMBRAER Service Bulletin 170-36-0004, Revision
01, dated March 10, 2008, for the actions required by this
paragraph. Repeat the replacement thereafter at intervals not to
exceed 3,000 flight hours.
(h) Retained Provision for Removed Check Valves from RH Engine
This paragraph restates the provision specified in paragraph (g)
of AD 2010-14-14, Amendment 39-16359 (75 FR 42585, July 22, 2010).
Although EMBRAER Alert Service Bulletin 170-36-A004, dated September
28, 2005, specifies to send removed check valves to the
manufacturer, this AD does not include that requirement.
(i) Retained Replacement for Left-Hand (LH) Engine on Model ERJ 170
Airplanes
This paragraph restates requirements of paragraph (h) of AD
2010-14-14, Amendment 39-16359 (75 FR 42585, July 22, 2010). For
Model ERJ 170-100 LR, -100 STD, -100 SE, -100 SU, -200 LR, -200 STD,
and -200 SU airplanes equipped with LPCVs having P/N 1001447-3:
Within 300 flight hours after September 13, 2007 (the effective date
of AD 2007-16-09, Amendment 39-15148 (72 FR 44734, August 9, 2007)),
or prior to the accumulation of 3,000 total flight hours, whichever
occurs later, replace the low-stage check valve and associated seals
of the LH engine's engine bleed system with a new check valve and
new seals, in accordance with paragraph 3.B. of the Accomplishment
Instructions of EMBRAER Service Bulletin 170-36-0004, dated November
18, 2005, or Revision 01, dated March 10, 2008. As of August 26,
2010 (the effective date of AD 2010-14-14), only use EMBRAER Service
Bulletin 170-36-0004, Revision 01, dated March 10, 2008. Repeat the
replacement thereafter at intervals not to exceed 3,000 flight
hours.
(j) Retained Provision for Removed Check Valves from LH Engine
This paragraph restates the provision specified in paragraph (i)
of AD 2010-14-14, Amendment 39-16359 (75 FR 42585, July 22, 2010).
Although EMBRAER Service Bulletin 170-36-0004, dated November 18,
2005, specifies to send removed check valves to the manufacturer,
this AD does not include that requirement.
(k) Retained Actions and Compliance With Revised Service Information
This paragraph restates the requirements of paragraph (j) of AD
2010-14-14, Amendment 39-16359 (75 FR 42585, July 22, 2010), with
revised service information for paragraphs (k)(3), (k)(7), and
(k)(8) of this AD. Unless already done, do the following actions.
(1) For Model ERJ 170-200 LR, -200 STD, and -200 SU airplanes
equipped with LPCVs having P/N 1001447-3: Within 100 flight hours
after August 26, 2010 (the effective date of AD 2010-14-14,
Amendment 39-16359 (75 FR 42585, July 22, 2010)), or prior to the
accumulation of 3,000 total flight hours, whichever occurs later,
replace the low-stage check valve and associated seals of the RH
engine's engine bleed system with a new check valve and new seals,
in accordance with the Accomplishment Instructions of EMBRAER
Service Bulletin 170-36-0004, Revision 01, dated March 10, 2008.
Repeat the replacement thereafter at intervals not to exceed 3,000
flight hours.
(2) For Model ERJ 170-100 LR, -100 STD, -100 SE, -100 SU, -200
LR, -200 STD, and -200 SU airplanes equipped with LPCVs having P/N
1001447-3: Replacing the LPCV having P/N 1001447-3 with a new one
having P/N 1001447-4, in accordance with the Accomplishment
Instructions of EMBRAER Service Bulletin 170-36-0011, Revision 02,
dated July 19, 2007, terminates the repetitive replacements required
by paragraphs (g), (i), and (k)(1) of this AD.
(3) For Model ERJ 170-100 LR, -100 STD, -100 SE, -100 SU, -200
LR, -200 STD, and -200 SU airplanes equipped with LPCVs having P/N
1001447-3, at the earlier of the times specified in paragraphs
(k)(3)(i) and (k)(3)(ii) of this AD, revise the maintenance program
to include maintenance Task 36-11-02-002 (Low Stage Bleed Check
Valve), specified in Section 1 of the EMBRAER 170 Maintenance Review
Board Report (MRBR), MRB-1621, Revision 6, dated January 14, 2010;
or Revision 7, dated November 11, 2010. Thereafter, except as
provided by paragraph (q) of this AD, no alternative inspection
intervals may be approved for the task.
(i) Within 180 days after accomplishing paragraph (k)(2) of this
AD.
(ii) Before any LPCV having P/N 1001447-4 accumulates 3,000
total flight hours, or within 300 flight hours after August 26, 2010
(the effective date of AD 2010-14-14, Amendment 39-16359 (75 FR
42585, July 22, 2010)), whichever occurs later.
(4) For Model ERJ 170-100 LR, -100 STD, -100 SE, -100 SU, -200
LR, -200 STD, and -200 SU airplanes equipped with LPCVs having P/N
1001447-3: As of August 26, 2010 (the effective date of AD 2010-14-
14, Amendment 39-16359 (75 FR 42585, July 22, 2010)), no person may
install any LPCV identified in paragraph (k)(4)(i) or (k)(4)(ii) of
this AD on any airplane.
(i) Any LPCV having P/N 1001447-3, installed on Model ERJ 170
airplanes, that has accumulated more than 3,000 total flight hours.
(ii) Any LPCV having P/N 1001447-3, installed on Model ERJ 170
and ERJ 190 airplanes, that has accumulated 3,000 or more total
flight hours. For Model ERJ 170 airplanes: To install an LPCV having
P/N 1001447-3 which was previously installed on a Model ERJ 190
airplane, calculate the equivalent number of flight hours by
multiplying the flight hours accumulated on the Model ERJ 190
airplane by a factor of 2 (100 percent).
(5) For Model ERJ 190-100 ECJ, -100 LR, -100 IGW, -100 STD, -200
STD, -200 LR, and -200 IGW airplanes: Within 100 flight hours after
August 26, 2010 (the effective date of AD 2010-14-14, Amendment 39-
16359 (75 FR 42585, July 22, 2010)), replace all LPCVs having P/N
1001447-3 that have accumulated 1,500 total flight hours or more as
of August 26, 2010 (the effective date of AD 2010-14-14), with a new
or serviceable LPCV having P/N 1001447-4 that has accumulated less
than 2,000 total flight hours since new or since overhaul, in
accordance with the Accomplishment Instructions of EMBRAER Service
Bulletin 190-36-0006, Revision 01, dated July 19, 2007.
(6) For Model ERJ 190-100 ECJ, -100 LR, -100 IGW, -100 STD, -200
STD, -200 LR, and -200 IGW airplanes: Replace all LPCVs having P/N
1001447-3 that have accumulated less than 1,500 total flight hours
as of August 26, 2010 (the effective date of AD 2010-14-14,
Amendment 39-16359 (75 FR 42585, July 22, 2010)), before the LPCV
accumulates 1,500 total flight hours or within 100 flight hours
after August 26, 2010 (the effective date of AD 2010-14-14),
whichever occurs later. Replace that LPCV with a new
[[Page 39570]]
or serviceable LPCV having P/N 1001447-4 that has accumulated less
than 2,000 total flight hours since new or since overhaul, in
accordance with the Accomplishment Instructions of EMBRAER Service
Bulletin 190-36-0006, Revision 01, dated July 19, 2007.
(7) For Model ERJ 190-100 ECJ, -100 LR, -100 IGW, -100 STD, -200
STD, -200 LR, and -200 IGW airplanes: Within 200 flight hours after
August 26, 2010 (the effective date of AD 2010-14-14, Amendment 39-
16359 (75 FR 42585, July 22, 2010)), or before any LPCV having P/N
1001447-4 installed on the right engine accumulates 2,000 total
flight hours since new or since overhaul, whichever occurs later,
replace the valve with a new or serviceable LPCV having P/N 1001447-
4 that has accumulated less than 2,000 total flight hours since new
or since overhaul, in accordance with the Accomplishment
Instructions of EMBRAER Service Bulletin 190-36-0014, Revision 01,
dated January 14, 2009 (for Model ERJ 190-100 STD, -100 LR, and -100
IGW, -200 STD, -200 LR, and -200 IGW airplanes); or EMBRAER Service
Bulletin 190LIN-36-0004, dated December 23, 2009 (for Model 190-100
ECJ airplanes). Repeat the replacement on the right engine at
intervals not to exceed 2,000 total flight hours on the LPCV since
new or last overhaul.
(8) For Model ERJ 190-100 ECJ, -100 LR, -100 IGW, -100 STD, -200
STD, -200 LR, and -200 IGW airplanes: Within 200 flight hours after
August 26, 2010 (the effective date of AD 2010-14-14, Amendment 39-
16359 (75 FR 42585, July 22, 2010)), or before any LPCV having P/N
1001447-4 installed on the left engine accumulates 2,000 total
flight hours since new or last overhaul, whichever occurs later,
replace the valve with a new or serviceable LPCV having P/N 1001447-
4 that has accumulated less than 2,000 total flight hours since new
or since overhaul, in accordance with the Accomplishment
Instructions of EMBRAER Service Bulletin 190-36-0014, Revision 01,
dated January 14, 2009 (for Model ERJ 190-100 STD, -100 LR, and -100
IGW, -200 STD, -200 LR, and -200 IGW airplanes); or EMBRAER Service
Bulletin 190LIN-36-0004, dated December 23, 2009 (for Model 190-100
ECJ airplanes). Repeat the replacement on the left engine at
intervals not to exceed 2,000 total flight hours on the LPCV since
new or last overhaul.
(9) For Model ERJ 190-100 ECJ, -100 LR, -100 IGW, -100 STD, -200
STD, -200 LR, and -200 IGW airplanes: As of August 26, 2010 (the
effective date of AD 2010-14-14, Amendment 39-16359 (75 FR 42585,
July 22, 2010)), installation on the left and right engines with an
LPCV having P/N 1001447-4 is allowed only if the valve has
accumulated less than 2,000 total flight hours since new or last
overhaul prior to installation.
(10) For Model ERJ 190-100 ECJ, -100 LR, -100 IGW, -100 STD, -
200 STD, -200 LR, and -200 IGW airplanes: As of August 26, 2010 (the
effective date of AD 2010-14-14, Amendment 39-16359 (75 FR 42585,
July 22, 2010)), no LPCV having P/N 1001447-3 may be installed on
any airplane. Any LPCV having P/N 1001447-3 already installed on an
airplane may remain in service until reaching the flight-hour limit
defined in paragraphs (k)(5) and (k)(6) of this AD.
(l) New Terminating Action
For Model ERJ 190-100 STD, -100 LR, -100 ECJ, and -100 IGW
airplanes; and Model ERJ 190-200 STD, -200 LR, and -200 IGW
airplanes: Except as provided by paragraph (m) of this AD, within 10
months after the effective date of this AD, install a new LPCV
having P/N 1001447-6, in accordance with paragraph (l)(1) or (l)(2)
of this AD. Installation of P/N 1001447-6 terminates the requirement
for installation and repetitive replacements of the LPCV P/N
1001447-3 or 1001447-4 required by paragraph (k) of this AD.
(1) Using a method approved by either the Manager, International
Branch, ANM-116, Transport Airplane Directorate, FAA; or
Ag[ecirc]ncia Nacional de Avia[ccedil][atilde]o Civil (ANAC) (or its
delegated agent).
(2) The Accomplishment Instructions of EMBRAER Service Bulletins
190-36-0014, Revision 01, dated January 14, 2009 (for Model ERJ 190-
100 STD, -100 LR, and -100 IGW, -200 STD, -200 LR, and -200 IGW
airplanes), and 190-LIN-36-0004, dated December 23, 2009 (for Model
190-100 ECJ airplanes). The service information has instructions to
install P/N 1001447-4, but can also be used to install P/N 1001447-
6.
(m) New Exception to Paragraph (l) of This AD
For Model ERJ 190-100 STD, -100 LR, -100 ECJ, and -100 IGW
airplanes; and Model ERJ 190-200 STD, -200 LR, and -200 IGW
airplanes; on which an LPCV, P/N 1001447-4, has been installed
before the compliance time specified in paragraph (l) of this AD:
Prior to the accumulation of 2,000 flight hours on the part since
new or overhauled, install a new LPCV having P/N 1001447-6, in
accordance with paragraph (m)(1) or (m)(2) of this AD.
(1) Using a method approved by either the Manager, International
Branch, ANM-116, Transport Airplane Directorate, FAA; or ANAC (or
its delegated agent).
(2) The Accomplishment Instructions of EMBRAER Service Bulletin
170-36-0011, Revision 2, dated July 19, 2007. The service
information has instructions to install P/N 1001447-4, but can also
be used to install P/N 1001447-6.
(n) New Optional Terminating Action
For Model ERJ 170-100 LR, -100 STD, -100 SE, and -100 SU
airplanes; and Model ERJ 170-200 LR, -200 SU, and -200 STD
airplanes: Installation of a new LPCV having P/N 1001447-6
terminates the requirement for installation and repetitive
replacements of the LPCV, P/N 1001447-3 or 1001447-4, required by
paragraph (k) of this AD.
Note 1 to paragraph (n) of this AD: Guidance for installing P/N
1001447-6 can be found in EMBRAER Service Bulletin 170-36-0011,
Revision 2, dated July 19, 2007. The service information has
instructions to install P/N 1001447-4, but can also be used to
install P/N 1001447-6.
(o) Credit for Previous Actions
(1) This paragraph provides credit for the actions specified in
paragraph (k)(2) of this AD, if those actions were performed before
August 26, 2010 (the effective date of AD 2010-14-14, Amendment 39-
16359 (75 FR 42585, July 22, 2010)), using EMBRAER Service Bulletin
170-36-0011, dated January 9, 2007; or EMBRAER Service Bulletin 170-
36-0011, Revision 01, dated May 28, 2007; which are not incorporated
by reference in this AD.
(2) This paragraph provides credit for the actions specified in
paragraphs (k)(5) and (k)(6) of this AD, if those actions were
performed before August 26, 2010 (the effective date of AD 2010-14-
14, Amendment 39-16359 (75 FR 42585, July 22, 2010)), using EMBRAER
Service Bulletin 190-36-0006, dated April 9, 2007, which is not
incorporated by reference in this AD.
(3) This paragraph provides credit for the actions specified in
paragraph (k)(1) of this AD, if those actions were performed before
August 26, 2010 (the effective date of AD 2010-14-14, Amendment 39-
16359 (75 FR 42585, July 22, 2010)), using EMBRAER Service Bulletin
170-36-0004, dated November 18, 2005, which is not incorporated by
reference in this AD.
(4) This paragraph provides credit for the actions specified in
paragraph (k)(3) of this AD, if those actions were done before
August 26, 2010 (the effective date of AD 2010-14-14, Amendment 39-
16359 (75 FR 42585, July 22, 2010)), using Task 36-11-02-002 (Low
Stage Bleed Check Valve) specified in Section 1 of the EMBRAER 170
Maintenance Review Board Report (MRBR), MRB-1621, Revision 5, dated
November 5, 2008, which is not incorporated by reference in this AD.
(p) New Parts Installation Limitations
(1) For Model ERJ 170-100 LR, -100 STD, -100 SE., and -100 SU
airplanes; and Model ERJ 170-200 LR, -200 SU, and -200 STD
airplanes: As of the effective date of this AD, no person may
install on any airplane an LPCV having P/N 1001447-4 that was
previously installed on any Model ERJ-190 airplane unless the valve
has been overhauled.
(2) For Model ERJ 190-100 STD, -100 LR, -100 ECJ, and -100 IGW
airplanes; and Model ERJ 190-200 STD, -200 LR, and -200 IGW
airplanes: As of the effective date of this AD, and until the
effective date specified in paragraph (p)(3) of this AD, no person
may install on any airplane an LPCV having P/N 1001447-4 that was
previously installed on any Model ERJ-170 airplane unless the valve
has been overhauled.
(3) For Model ERJ 190-100 STD, -100 LR, -100 ECJ, and -100 IGW
airplanes; and Model ERJ 190-200 STD, -200 LR, and -200 IGW
airplanes: As of 10 months after the effective date of this AD, no
person may install any LPCV having P/N 1001447-4 on any airplane.
(q) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager,
International Branch, ANM-116, Transport Airplane
[[Page 39571]]
Directorate, FAA, has the authority to approve AMOCs for this AD, if
requested using the procedures found in 14 CFR 39.19. In accordance
with 14 CFR 39.19, send your request to your principal inspector or
local Flight Standards District Office, as appropriate. If sending
information directly to the International Branch, send it to ATTN:
Cindy Ashforth, Aerospace Engineer, International Branch, ANM-116,
Transport Airplane Directorate, FAA, 1601 Lind Avenue SW., Renton,
WA 98057-3356; telephone (425) 227-2768; fax (425) 227-1149.
Information may be emailed to: <a href="/cdn-cgi/l/email-protection#261f0b67686b0b1717100b676b69650b74637773637572756640474708414950"><span class="__cf_email__" data-cfemail="073e2a46494a2a3636312a464a48442a55425652425453544761666629606871">[email protected]</span></a>.
Before using any approved AMOC, notify your appropriate principal
inspector, or lacking a principal inspector, the manager of the
local flight standards district office/certificate holding district
office. The AMOC approval letter must specifically reference this
AD.
(2) Airworthy Product: For any requirement in this AD to obtain
corrective actions from a manufacturer or other source, use these
actions if they are FAA-approved. Corrective actions are considered
FAA-approved if they are approved by the State of Design Authority
(or their delegated agent). You are required to assure the product
is airworthy before it is returned to service.
(3) AMOCs approved previously in accordance with AD 2010-14-14,
Amendment 39-16359 (75 FR 42585, July 22, 2010), are not approved as
AMOCs for this AD.
(r) Related Information
(1) Refer to MCAI Brazilian Airworthiness Directive 2005-09-
03R3, effective May 30, 2011 (<a href="http://www2.anac.gov.br/certificacao/da/Textos/1336amd.pdf">http://www2.anac.gov.br/certificacao/da/Textos/1336amd.pdf</a>); Brazilian Airworthiness Directive 2006-11-
01R6, effective May 30, 2011 (<a href="http://www2.anac.gov.br/certificacao/DA/Textos/1337amd.pdf">http://www2.anac.gov.br/certificacao/DA/Textos/1337amd.pdf</a>); for related information.
(2) Service information identified in this AD that is not
incorporated by reference in this AD may be obtained at the
addresses specified in paragraphs (s)(7) and (s)(8) of this AD.
(s) Material Incorporated by Reference
(1) The Director of the Federal Register approved the
incorporation by reference (IBR) of the service information listed
in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
(2) You must use this service information as applicable to do
the actions required by this AD, unless the AD specifies otherwise.
(3) The following service information was approved for IBR on
August 6, 2013.
(i) EMBRAER Service Bulletin 190LIN-36-0004, dated December 23,
2009.
(ii) Task 36-11-02-002 (Low Stage Bleed Check Valve) specified
in Section 1 of the EMBRAER 170 Maintenance Review Board Report
(MRBR), MRB-1621, Revision 7, dated November 11, 2010.
(4) The following service information was approved for IBR on
August 26, 2010 (75 FR 42585, July 22, 2010).
(i) EMBRAER Service Bulletin 170-36-0004, Revision 01, dated
March 10, 2008.
(ii) EMBRAER Service Bulletin 170-36-0011, Revision 02, dated
July 19, 2007.
(iii) EMBRAER Service Bulletin 190-36-0006, Revision 01, dated
July 19, 2007.
(iv) EMBRAER Service Bulletin 190-36-0014, Revision 01, dated
January 14, 2009.
(v) Task 36-11-02-002 (Low Stage Bleed Check Valve) specified in
Section 1 of the EMBRAER 170 MRBR MRB-1621, Revision 6, dated
January 14, 2010.
(5) The following service information was approved for IBR on
September 13, 2007 (72 FR 44734, August 9, 2007).
(i) EMBRAER Service Bulletin 170-36-0004, dated November 18,
2005.
(ii) Reserved.
(6) The following service information was approved for IBR on
November 29, 2005 (70 FR 69075, November 14, 2005).
(i) EMBRAER Alert Service Bulletin 170-36-A004, dated September
28, 2005.
(ii) Reserved.
(7) For service information identified in this AD, contact
Embraer S.A., Technical Publications Section (PC 060), Av.
Brigadeiro Faria Lima, 2170--Putim--12227-901 S[atilde]o Jose dos
Campos-SP--BRASIL; telephone +55 12 3927-5852 or +55 12 3309-0732;
fax +55 12 3927-7546; email <a href="/cdn-cgi/l/email-protection#7e1a170d0a0c171c3e1b131c0c1f1b0c501d1113501c0c"><span class="__cf_email__" data-cfemail="81e5e8f2f5f3e8e3c1e4ece3f3e0e4f3afe2eeecafe3f3">[email protected]</span></a>; Internet <a href="http://www.flyembraer.com">http://www.flyembraer.com</a>.
(8) You may review copies of the service information at the FAA,
Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA.
For information on the availability of this material at the FAA,
call 425-227-1221.
(9) You may view this service information that is incorporated
by reference at the National Archives and Records Administration
(NARA). For information on the availability of this material at
NARA, call 202-741-6030, or go to: <a href="http://www.archives.gov/federal-register/cfr/ibr-locations.html">http://www.archives.gov/federal-register/cfr/ibr-locations.html</a>.
Issued in Renton, Washington, on May 29, 2013.
Jeffrey E. Duven,
Acting Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 2013-15637 Filed 7-1-13; 8:45 am]
BILLING CODE 4910-13-P
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.