AD 2013-04-07

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier, Inc. Airplanes

AD Number
2013-04-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2012-0861
FR Citation
78 FR 14158

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition

Loss of the fixed frequency system, leading to the loss of power to the left and right buses and all systems serviced by these buses.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Incorporate wiring modifications specified in Bombardier Service Bulletin 8-24-87, Revision B, dated April 3, 2012. Revise the airplane maintenance program by incorporating Task 2420/13, Operational Check of Relays K4, K5, K6, and K7.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 6,000 flight hours or 36 months after the effective date, whichever occurs first, for wiring modifications. Within 30 days after the effective date for maintenance program revision.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc. Model DHC-8-102, -103, -106, -201, -202, -301, -311, and -315 airplanes, serial numbers 002 through 672 inclusive.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain