AD 2012-13-09

Recurring final rule
Data completeness: 70%

Airworthiness Directives; The Boeing Company Airplanes

AD Number
2012-13-09
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2010-1115
FR Citation
77 FR 41041

Applicability

TypeManufacturerModelDetails
aircraft Boeing Company Airworthiness Directives; The Boeing Company Airplanes

Unsafe Condition

Electrical arcs at terminal 'A' of the electrically heated flight deck window 1, which could lead to smoke and fire in the cockpit, loss of visibility, and injuries to or incapacitation of the flight crew.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Conduct repetitive inspections for damage of the electrical connections at terminal 'A' of the left and right flight deck window 1. Take corrective actions if necessary. Replace flight deck window 1 with a new improved window equipped with different electrical connections to terminate repetitive inspections for that window.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 500 flight hours after the effective date of the AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

The Boeing Company Model 747-100, 747-100B, 747-100B SUD, 747-200B, 747-200C, 747-200F, 747-300, 747-400, 747-400D, 747-400F, 747SR, and 747SP series airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.