AD 2011-21-13
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Eurocopter | Deutschland GmbH (ECD) Model MBB-BK 117 C-2 | Airworthiness Directives; Eurocopter Deutschland GmbH (ECD) Model MBB-BK 117 C-2 Helicopters |
Unsafe Condition
Reports of too high a current flow when one generator is deactivated, which could lead to failure of the remaining generator, loss of electrical power, and loss of systems necessary for flight safety.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Revise the Rotorcraft Flight Manual (RFM) by inserting temporary pages 7, 8, and 11 from Alert Service Bulletin ASB MBB BK117 C-2-24A-008 into the Emergency Procedures and Performance Data sections. The revisions alert operators to visually monitor the power display GEN AMPS on the VEMD for too high a current flow when a generator is deactivated and provide instructions to switch off the two BUS TIEs on the overhead panel to prevent generator damage.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Eurocopter Deutschland GmbH (ECD) Model MBB-BK 117 C-2 helicopters.
AI-generated summary from the source AD text. Verify against the official source before acting.