AD 2011-09-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc. Model CL-600-2A12 (CL-601) and CL-600-2B16 (CL-601-3A, CL-601-3R, and CL-604 Variants) Airplanes |
Unsafe Condition
Wing Anti-icing system failures due to potential cracking of the wing anti-ice duct piccolo-tube and leading edge thermal switches malfunction.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the wing anti-ice duct piccolo-tube and perform functional tests on the leading edge thermal switches. Complete tasks 30-11-00-101, 30-11-00-102, 36-21-00-101, and 57-10-00-208 as specified in the applicable manuals. Compliance with Bombardier Service Bulletin 601-0590 is required where applicable.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 240 or 320 flight hours after the effective date of this AD, depending on the model and serial number.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model CL-600-2A12 (CL-601) serial numbers 3001-3066 and CL-600-2B16 (CL-601-3A, CL-601-3R, CL-604 Variants) serial numbers 5001-5194, 5301-5665, and 5701 onwards, where applicable service bulletins have been accomplished.
AI-generated summary from the source AD text. Verify against the official source before acting.