AD 2011-03-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | The Boeing Company | MD-90-30 | Airworthiness Directives; The Boeing Company Model MD-90-30 Airplanes |
Unsafe Condition
Possible latent failure in the fire handle shutoff relay circuit due to a lack of separation between engine wires.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install new fire handle shutoff system wiring in accordance with Boeing Alert Service Bulletin MD90-74A002.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 4,200 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
The Boeing Company Model MD-90-30 airplanes, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
We are adopting a new airworthiness directive (AD) for the products listed above. This AD requires installing new fire handle shutoff system wiring. This AD was prompted by a possible latent failure in the fire handle shutoff relay circuit due to a lack of separation between engine wires. We are issuing this AD to minimize the possibility of a multiple engine shutdown due to single fire handle activation.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 76, Number 25 (Monday, February 7, 2011)]
[Rules and Regulations]
[Pages 6535-6536]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 2011-2428]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2010-1043; Directorate Identifier 2010-NM-200-AD;
Amendment 39-16593; AD 2011-03-09]
RIN 2120-AA64
Airworthiness Directives; The Boeing Company Model MD-90-30
Airplanes
AGENCY: Federal Aviation Administration (FAA), DOT.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are adopting a new airworthiness directive (AD) for the
products listed above. This AD requires installing new fire handle
shutoff system wiring. This AD was prompted by a possible latent
failure in the fire handle shutoff relay circuit due to a lack of
separation between engine wires. We are issuing this AD to minimize the
possibility of a multiple engine shutdown due to single fire handle
activation.
DATES: This AD is effective March 14, 2011.
The Director of the Federal Register approved the incorporation by
reference of a certain publication listed in the AD as of March 14,
2011.
ADDRESSES: For service information identified in this AD, contact
Boeing Commercial Airplanes, Attention: Data & Services Management,
3855 Lakewood Boulevard, MC D800-0019, Long Beach, California 90846-
0001; telephone 206-544-5000, extension 2; fax 206-766-5683; e-mail
<a href="/cdn-cgi/l/email-protection#afcbdcca81cdc0caccc0c2efcdc0cac6c1c881ccc0c2"><span class="__cf_email__" data-cfemail="b7d3c4d299d5d8d2d4d8daf7d5d8d2ded9d099d4d8da">[email protected]</span></a>; Internet <a href="https://www.myboeingfleet.com">https://www.myboeingfleet.com</a>. You may
review copies of the referenced service information at the FAA
Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton,
Washington. For information on the availability of this material at the
FAA, call 425-227-1221.
Examining the AD Docket
You may examine the AD docket on the Internet at <a href="http://www.regulations.gov">http://www.regulations.gov</a>; or in person at the Docket Management Facility
between 9 a.m. and 5 p.m., Monday through Friday, except Federal
holidays. The AD docket contains this AD, the regulatory evaluation,
any comments received, and other information. The address for the
Docket Office (phone: 800-647-5527) is Document Management Facility,
U.S. Department of Transportation, Docket Operations, M-30, West
Building Ground Floor, Room W12-140, 1200 New Jersey Avenue, SE.,
Washington, DC 20590.
FOR FURTHER INFORMATION CONTACT: William S. Bond, Aerospace Engineer,
Propulsion Branch, ANM-140L, FAA, Los Angeles Aircraft Certification
Office, 3960 Paramount Boulevard, Lakewood, CA 90712; phone: 562-627-
5253; fax: 562-627-5210; e-mail: <a href="/cdn-cgi/l/email-protection#683f010404010905462a07060c280e0909460f071e"><span class="__cf_email__" data-cfemail="26714f4a4a4f474b08644948426640474708414950">[email protected]</span></a>.
SUPPLEMENTARY INFORMATION:
Discussion
We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR
part 39 to include an airworthiness directive (AD) that would apply to
the specified products. That NPRM published in the Federal Register on
November 5, 2010 (75 FR 68245). That NPRM proposed to require
installing new fire handle shutoff system wiring.
Comments
We gave the public the opportunity to participate in developing
this AD. We received no comments on the NPRM or on the determination of
the cost to the public.
Explanation of Change Made to the AD
We have revised this AD to identify the legal name of the
manufacturer as published in the most recent type certificate data
sheet for the affected airplane models.
Conclusion
We reviewed the relevant data and determined that air safety and
the public interest require adopting the AD with the change described
previously. We also determined that this change will not increase the
economic burden on any operator or increase the scope of the AD.
Costs of Compliance
We estimate that this AD will affect 25 airplanes of U.S. registry.
We estimate the following costs to comply with this AD:
Estimated Costs
----------------------------------------------------------------------------------------------------------------
Cost on U.S.
Action Labor cost Parts cost Cost per product operators
----------------------------------------------------------------------------------------------------------------
Wiring change.................... 8 work-hours x $85 $489 $1,169 $29,225
per hour = $680.
----------------------------------------------------------------------------------------------------------------
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, section 106, describes the
authority of the FAA Administrator. Subtitle VII: Aviation Programs,
describes in more detail the scope of the Agency's authority.
We are issuing this rulemaking under the authority described in
subtitle VII, part A, subpart III, section 44701: ``General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
This AD will not have federalism implications under Executive Order
13132. This AD will not have a
[[Page 6536]]
substantial direct effect on the States, on the relationship between
the national government and the States, or on the distribution of power
and responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
(1) Is not a ``significant regulatory action'' under Executive
Order 12866,
(2) Is not a ``significant rule'' under DOT Regulatory Policies and
Procedures (44 FR 11034, February 26, 1979),
(3) Will not affect intrastate aviation in Alaska, and
(4) Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by adding the following new airworthiness
directive (AD):
2011-03-09 The Boeing Company: Amendment 39-16593; Docket No. FAA-
2010-1043; Directorate Identifier 2010-NM-200-AD.
Effective Date
(a) This AD is effective March 14, 2011.
Affected ADs
(b) None.
Applicability
(c) This AD applies to all The Boeing Company Model MD-90-30
airplanes, certificated in any category.
Subject
(d) Joint Aircraft System Component (JASC)/Air Transport
Association (ATA) of America Code 74, Ignition.
Unsafe Condition
(e) This AD was prompted by a possible latent failure in the
fire handle shutoff relay circuit due to a lack of separation
between engine wires. We are proposing this AD to minimize the
possibility of a multiple engine shutdown due to single fire handle
activation.
Compliance
(f) Comply with this AD within the compliance times specified,
unless already done.
Wire Installation
(g) Within 4,200 flight hours after the effective date of this
AD, install new fire handle shutoff system wiring, in accordance
with the Accomplishment Instructions of Boeing Alert Service
Bulletin MD90-74A002, dated August 17, 2010.
Alternative Methods of Compliance (AMOCs)
(h)(1) The Manager, Los Angeles Aircraft Certification Office,
FAA, has the authority to approve AMOCs for this AD, if requested
using the procedures found in 14 CFR 39.19. In accordance with 14
CFR 39.19, send your request to your principal inspector or local
Flight Standards District Office, as appropriate. If sending
information directly to the manager of the ACO, send it to the
attention of the person identified in the Related Information
section of this AD.
(2) Before using any approved AMOC, notify your appropriate
principal inspector, or lacking a principal inspector, the manager
of the local flight standards district office/certificate holding
district office.
Related Information
(i) For more information about this AD, contact William S. Bond,
Aerospace Engineer, Propulsion Branch, ANM-140L, FAA, Los Angeles
Aircraft Certification Office, 3960 Paramount Boulevard, Lakewood,
CA 90712-4137; phone: 562-627-5253; fax: 562-627-5210; e-mail:
<a href="/cdn-cgi/l/email-protection#4a1d232626232b27640825242e0a2c2b2b642d253c"><span class="__cf_email__" data-cfemail="1e49777272777f73305c71707a5e787f7f30797168">[email protected]</span></a>.
Material Incorporated by Reference
(j) You must use Boeing Alert Service Bulletin MD90-74A002,
dated August 17, 2010, to do the actions required by this AD, unless
the AD specifies otherwise.
(1) The Director of the Federal Register approved the
incorporation by reference of Boeing Alert Service Bulletin MD90-
74A002, dated August 17, 2010, under 5 U.S.C. 552(a) and 1 CFR part
51.
(2) For service information identified in this AD, contact
Boeing Commercial Airplanes, Attention: Data & Services Management,
3855 Lakewood Boulevard, MC D800-0019, Long Beach, California 90846-
0001; telephone 206-544-5000, extension 2; fax 206-766-5683; e-mail
<a href="/cdn-cgi/l/email-protection#ef8b9c8ac18d808a8c8082af8d808a868188c18c8082"><span class="__cf_email__" data-cfemail="87e3f4e2a9e5e8e2e4e8eac7e5e8e2eee9e0a9e4e8ea">[email protected]</span></a>; Internet <a href="https://www.myboeingfleet.com">https://www.myboeingfleet.com</a>.
(3) You may review copies of the service information at the FAA,
Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton,
Washington. For information on the availability of this material at
the FAA, call 425-227-1221.
(4) You may also review copies of the service information that
is incorporated by reference at the National Archives and Records
Administration (NARA). For information on the availability of this
material at an NARA facility, call 202-741-6030, or go to <a href="http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html">http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html</a>.
Issued in Renton, Washington, on January 26, 2011.
Ali Bahrami,
Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 2011-2428 Filed 2-4-11; 8:45 am]
BILLING CODE 4910-13-P
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.