AD 2011-01-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Aviat | Various | Airworthiness Directives; GROB-WERKE GMBH & CO KG Models G102 ASTIR CS, G102 CLUB ASTIR III, G102 CLUB ASTIR IIIb, and G102 STANDARD ASTIR III Gliders |
Unsafe Condition
Cracks have been found on the wing spigot assemblies installed on the G102 single-seat gliders. Several of these cracks were internal to the spigot and were not visually detectable until the component failed. Cracks in the wing spigot assembly pin-to-plate interface could cause the spar spigot to fail with little or no warning.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the wing main spigot assembly before the next flight and replace it on the G102 single-seat gliders.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
GROB-WERKE GMBH & CO KG Models G102 ASTIR CS, G102 CLUB ASTIR III, G102 CLUB ASTIR IIIb, and G102 STANDARD ASTIR III Gliders.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain