Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Aviat | Various | Airworthiness Directives; PIAGGIO AERO INDUSTRIES S.p.A. Model P-180 Airplanes |
Unsafe Condition
A short circuit between a generator power cable and an anti-ice shutoff valve, caused by chafing between the cable and the valve, leading to worn insulation. Investigation revealed insufficient clearance and vibrations due to inadequate clamping, which could result in short circuits, fire, or loss of critical aircraft systems.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect generator power cables for minimum clearance and insulation damage within 3 months of the effective date. If discrepancies are found, perform necessary corrective actions before further flight, following PIAGGIO AERO INDUSTRIES S.p.A. Service Bulletin 80-0271.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 3 months after March 11, 2010
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
PIAGGIO AERO INDUSTRIES S.p.A. Model P-180 airplanes, all serial numbers through 1180, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain