AD 2009-15-03

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier Model BD-700-1A10 and BD-700-1A11 Airplanes

AD Number
2009-15-03
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2009-0138
FR Citation
74 FR 34225

Applicability

TypeManufacturerModelDetails
aircraft Bombardier BD-700-1A10 and BD-700-1A11 Airworthiness Directives; Bombardier Model BD-700-1A10 and BD-700-1A11 Airplanes
aircraft Aviat Various Airworthiness Directives; Bombardier Model BD-700-1A10 and BD-700-1A11 Airplanes

Unsafe Condition

Seizure of the bearing on the PCU rod end can damage the attachment fitting bushing and fracture the bolt connecting the PCU to the elevator surface. Failure of both PCU bolts on one side could result in disconnection of the elevator control surface, leading to flutter and loss of the aircraft.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect all PCU attachment joints for damage and seizure (including signs of seizure). Inspect PCU attachment joint components for damage (including wear damage, fretting, corrosion, galling, scoring, fretting wear, and parts not meeting inspection requirements). Perform applicable corrective actions.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier Model BD-700-1A10 and BD-700-1A11 airplanes, serial numbers 9002 through 9222 inclusive, equipped with elevator power control units (PCUs) having part numbers GT411-3800-5 or GT411-3800-7.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗