AD 2009-06-17

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

AD Number
2009-06-17
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2008-0521
FR Citation
74 FR 13086

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes
aircraft Aviat Various Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition

Failure of the Air-Driven generators (ADGs) due to a short circuit between internal wires and metallic over-braided shields, which could result in the ADG not providing power when deployed.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect and modify the ADG internal wiring if required. Prohibit future installation of unmodified ADGs.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 12 months after the effective date of the AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, specifically those with affected ADGs installed or capable of having them installed.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.