AD 2008-16-08
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dassault | Falcon 2000EX | Airworthiness Directives; Dassault Model Falcon 2000EX Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; Dassault Model Falcon 2000EX Airplanes |
Unsafe Condition
Large electrical transients on the essential bus bar may cause simultaneous and temporary power shortage on both sides of the electrical system, leading to a momentary loss of data on the EFIS screens.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the GCU electrical wiring as instructed in Dassault Service Bulletin F2000EX-141, Revision 1, dated November 26, 2007.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 13 months after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dassault Model Falcon 2000EX airplanes from serial number 1 to 107 inclusive, certificated in any category; which have not been modified by Dassault Service Bulletin (SB) F2000EX-141.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.