AD 2008-13-23
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Aviat | Various | Airworthiness Directives; Dornier Model 328-100 Airplanes |
Unsafe Condition
Water or ice accumulating in the elevator assembly, which could result in corrosion and consequent reduced structural integrity of the flight control surface, or an unbalanced flight control surface.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install a drain hole in the lower skin of the left and right-hand elevator horns in accordance with the Accomplishment Instructions of Avcraft Dornier Service Bulletin SB-328-55-450, Revision 1, dated November 19, 2003.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 90 days after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All Dornier Model 328-100 airplanes, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.