AD 2008-04-12
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | 767-200 | Airworthiness Directives; Boeing Model 767-200, -300, -300F, and -400ER Series Airplanes |
Unsafe Condition
Loss of all direct current (DC) power generation during flight due to inadequate electrical ground path between the ground bracket of the transformer rectifier units (TRUs)/main battery charger (MBC) and the structure.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install a new ground stud bracket using faying surface bonding. Measure the resistance from the bracket to the structure and the ground lugs to the bracket using a bonding meter.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Boeing Model 767-200, -300, -300F, and -400ER series airplanes, as specified in the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.