AD 2007-16-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Embraer | ERJ 170-100 LR | Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 Airplanes and Model ERJ 190 Airplanes |
Unsafe Condition
Failure of the low-stage check valve to close, which could result in an engine shutting down during flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Repetitively replace the low-stage check valve and associated seals of the right-hand engine bleed system. Additionally, repetitively replace the low-stage check valve and associated seals of the left-hand engine bleed system with a new check valve and new seals.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 100 flight hours after November 29, 2005, or prior to the accumulation of 3,000 total flight hours, whichever occurs later.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All EMBRAER Model ERJ 170-100 LR, -100 STD, -100 SE, -100 SU, -200 LR, -200 STD, and -200 SU airplanes; and Model ERJ 190-100 STD, -100 LR, and -100 IGW airplanes, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain