AD 2007-07-11
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Gulfstream | Aerospace LP Model Gulfstream 200 | Airworthiness Directives; Gulfstream Aerospace LP Model Gulfstream 200 Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; Gulfstream Aerospace LP Model Gulfstream 200 Airplanes |
Unsafe Condition
Due to quality escape during serial production, the jumpers at the Right Fuel Standby Pump Connector 4Q1 were manufactured from 14 AWG electrical wiring instead of 12 AWG wires as required per approved drawing. The possible overheating of the 14 AWG jumpers routed in vicinity of the fuel tank may present the unsafe flight condition.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the wiring, inspect for other components damaged by overheating, and replace damaged components if necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 25 flight hours or 30 days, whichever occurs first, after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Gulfstream Aerospace LP Model Gulfstream 200 airplanes, certificated in any category, serial numbers 121 through 154.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.