AD 2006-17-14
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes |
Unsafe Condition
Incidents of short circuit failures of certain alternating current (AC) contactors located in the avionics bay.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 800 flight hours or four months after the effective date, perform a general visual inspection of AC service bus contactors 1K4XD and 2K4XD, part number D-18ZZA, and utility bus contactor K4XA, part number D-7GRZ, to determine if they have an Ultem 2200 terminal base plate. Apply RTV sealant to the terminal base plate as applicable, following the Accomplishment Instructions in Bombardier Service Bulletin 601R-24-122, Revision A.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 800 flight hours or four months after the effective date, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, certificated in any category, serial numbers 7003 through 7990 inclusive and 8000 and subsequent.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain