AD 2006-10-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Embraer | Various | Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model EMB-120, -120ER, -120FC, -120QC, and -120RT Airplanes in Operation |
Unsafe Condition
A potential source of ignition near a fuel tank, which, in combination with flammable fuel vapors, could result in a fuel tank explosion.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the protective tubes and conduits of the wiring harnesses of the refueling vent and pilot valves with non-conductive hoses; modify the harness wiring and supports; and reroute the harnesses to prevent interference with adjacent strobe light connectors, as applicable.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 5,000 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All EMBRAER Model EMB-120, -120ER, -120FC, -120QC, and -120RT airplanes in operation, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain