AD 2005-16-14

final rule
Data completeness: 70%

Airworthiness Directives; Gulfstream Model G-IV, GIV-X, GV, and GV-SP Series Airplanes

AD Number
2005-16-14
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2005-22074
FR Citation
70 FR 47722

Applicability

TypeManufacturerModelDetails
aircraft Gulfstream G-IV Airworthiness Directives; Gulfstream Model G-IV, GIV-X, GV, and GV-SP Series Airplanes

Unsafe Condition

Short-circuiting of the Adel Wiggins floor heater pad system, which could result in a fire in the airplane cabin.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the airplane to determine if an Adel Wiggins floor heater pad system is installed. If installed, deactivate the system by capping and stowing all associated electrical wiring, opening and collaring each associated circuit breaker, and labeling each collared circuit breaker inoperative.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Gulfstream Model G-IV, GIV-X, GV, and GV-SP series airplanes, including specific models G300, G350, G400, G450, G500, and G550, where the Adel Wiggins floor heater pad system is installed.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.