AD 2005-16-14
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Gulfstream | G-IV | Airworthiness Directives; Gulfstream Model G-IV, GIV-X, GV, and GV-SP Series Airplanes |
Unsafe Condition
Short-circuiting of the Adel Wiggins floor heater pad system, which could result in a fire in the airplane cabin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the airplane to determine if an Adel Wiggins floor heater pad system is installed. If installed, deactivate the system by capping and stowing all associated electrical wiring, opening and collaring each associated circuit breaker, and labeling each collared circuit breaker inoperative.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Gulfstream Model G-IV, GIV-X, GV, and GV-SP series airplanes, including specific models G300, G350, G400, G450, G500, and G550, where the Adel Wiggins floor heater pad system is installed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain