AD 2005-13-34
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | 777-200 and -300 | Airworthiness Directives; Boeing Model 777-200 and -300 Series Airplanes |
Unsafe Condition
Overheating of ceiling and sidewall light connectors in the passenger cabin, which could result in smoke and a possible fire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace existing ceiling and sidewall light connectors in the passenger cabin with new connectors that are more resistant to moisture contamination. Follow-on actions as specified in the service bulletin are also required.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 60 months of the effective date.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Boeing Model 777-200 and -300 series airplanes with line numbers 1 through 264 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.