AD 2005-13-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Avcraft | Dornier Model 328-100 and -300 | Airworthiness Directives; Avcraft Dornier Model 328-100 and -300 Airplanes |
Unsafe Condition
Blockage within the fuselage drain lines, causing fluids to collect. These fluids may freeze and expand, damaging the drain lines, and allowing fuel to leak into the cabin and fuel vapors to come into contact with ignition sources, which could result in a fire in the cabin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform an initial pressure test and any applicable related investigative and corrective actions. After the pressure test, perform a detailed inspection and related investigative and corrective actions.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Initial pressure test within 4 months after the effective date; detailed inspection within 24 months after the effective date.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
AvCraft Dornier Model 328-100 series airplanes having serial numbers 3005 through 3119 inclusive, and AvCraft Dornier Model 328-300 series airplanes without option 033F003 'Extended Range' installed; certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain