AD 2005-10-20
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | 777-200 | Airworthiness Directives; Boeing Model 777-200 Series Airplanes |
Unsafe Condition
Reports indicate that the 'FUEL LOW CENTER' message does not activate when the fuel level in the center tank is low, which could lead to the fuel pumps in the center fuel tank running dry and becoming a potential ignition source, resulting in a fuel tank explosion.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the pressure switches on the override/jettison fuel pumps with new pressure switches, and replace the ship side electrical connectors for the pressure switches on override/jettison fuel pumps with new connectors, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-28-0036.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 24 months after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Boeing Model 777-200 series airplanes, certificated in any category, as identified in Boeing Special Attention Service Bulletin 777-28-0036, dated September 2, 2004. Excludes Boeing Model 777-200ER series airplanes, which have a larger center wing tank and a different pump inlet configuration.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain