AD 2005-09-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Cessna | 750 | Airworthiness Directives; Cessna Model 750 Airplanes |
Unsafe Condition
Interference between the APU fuel tube assembly and elevator flight control cables, hydraulic lines, and high-temperature bleed air couplings can cause chafing, leading to fuel leaking into the tail cone area where ignition sources are present, potentially resulting in a fire in an area without fire detection or extinguishing provisions.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect for chafing damage on the APU fuel tube assembly and elevator control cables. Replace the APU fuel tube assembly or elevator control cable with new parts if chafing is found. Adjust routing of the APU fuel tube assembly to ensure adequate clearance from specified components. Report inspection results to Cessna.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Cessna Model 750 airplanes
AI-generated summary from the source AD text. Verify against the official source before acting.