AD 2005-01-17
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | EXTRA | Flugzeugbau GmbH Model EA-300 and EA-300/S | Airworthiness Directives; EXTRA Flugzeugbau GmbH Model EA-300 and EA-300/S Airplanes |
Unsafe Condition
Cracks in the upper longeron cutout-bridge could cause the upper longeron cutout-bridge to fail, resulting in structural damage to the fuselage and potentially leading to loss of control of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the upper longeron cutout-bridge for cracks. Repair any cracks found. Modify this area following the new service bulletin procedures. If Procedure II is used, replace the new bridges every 1,000 hours time-in-service (TIS).
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
EXTRA Flugzeugbau GmbH Model EA-300 and EA-300/S airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain