AD 2005-01-17

final rule
Data completeness: 70%

Airworthiness Directives; EXTRA Flugzeugbau GmbH Model EA-300 and EA-300/S Airplanes

AD Number
2005-01-17
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2004-19443
FR Citation
70 FR 2946

Applicability

TypeManufacturerModelDetails
aircraft EXTRA Flugzeugbau GmbH Model EA-300 and EA-300/S Airworthiness Directives; EXTRA Flugzeugbau GmbH Model EA-300 and EA-300/S Airplanes

Unsafe Condition

Cracks in the upper longeron cutout-bridge could cause the upper longeron cutout-bridge to fail, resulting in structural damage to the fuselage and potentially leading to loss of control of the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the upper longeron cutout-bridge for cracks. Repair any cracks found. Modify this area following the new service bulletin procedures. If Procedure II is used, replace the new bridges every 1,000 hours time-in-service (TIS).

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 50 flight hours after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

EXTRA Flugzeugbau GmbH Model EA-300 and EA-300/S airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain