AD 2004-19-05

final rule
Data completeness: 70%

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

AD Number
2004-19-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 2003-NM-69-AD
FR Citation
69 FR 56680

Applicability

TypeManufacturerModelDetails
aircraft McDonnell Douglas MD-11 and -11F Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition

Electrical arcing caused by power feeder cable terminal lugs grounding against terminal strip support brackets, which could result in smoke and fire in the main cabin or avionics compartment.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace applicable terminal strips in the avionics compartment with new strips, inspect wires for damage and repair or remove nameplates as necessary. Perform a general visual inspection to detect arcing damage of the surrounding structure and electrical cables in the avionics compartment. Repair or replace any damaged components before further flight. For certain airplanes, replace the terminal board in the aft passenger compartment.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 18 months after August 23, 2002, or before further flight if damage is detected.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

McDonnell Douglas Model MD-11 and -11F airplanes, as listed in Boeing Alert Service Bulletin MD11-24A178, Revision 02, dated March 11, 2003, and McDonnell Douglas Alert Service Bulletin MD11-24A177, dated July 18, 2003; certificated in any category.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.