AD 2004-12-15
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | 777-200 | Airworthiness Directives; Boeing Model 777-200 Series Airplanes |
Unsafe Condition
Damage to the stabilizer cutout circuit wires in the bundles due to contact between the bundles and the adjacent galley water drain tube and hydraulic tubes, which, if followed by an active fault in the stabilizer command circuit, could result in undesired stabilizer motion that cannot be stopped, and could lead to loss of pitch control and loss of control of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a one-time general visual inspection of the wire bundles routed aft of electrical disconnect panel AC2162 to determine their installation and separation. If wire bundles are not installed in accordance with the service bulletin, perform a detailed inspection for damage, repair all damage, and add clamps or tie strips to secure the wire bundles before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 18 months of the effective date
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Boeing Model 777-200 series airplanes, as listed in Boeing Service Bulletin 777-27-0057, dated August 22, 2002; certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain