AD 2004-11-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Fokker | F | Airworthiness Directives; Fokker Model F.28 Mark 0070 Series Airplanes |
Unsafe Condition
Improper installation of wires on certain contactors in the electrical power center (EPC) could lead to a short circuit, potentially causing a fire in the main cabin, damage to the airplane, or injury to passengers and flightcrew.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the 4 contactors with part number 9124-9283 in the EPC for proper wire installation. If incorrect, reinstall the wires according to Fokker Service Bulletin SBF100-24-035 before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 6 months after the effective date of the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Model F.28 Mark 0070 series airplanes, serial numbers 11521 and 11528 through 11585, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain