AD 2004-09-39
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Saab | SAAB 340B | Airworthiness Directives; Saab Model SAAB 340B Series Airplanes Equipped with Hamilton Sundstrand Propellers |
Unsafe Condition
Incorrectly installed 35-ampere (amp) remote controlled circuit breakers (RCCBs) on a 50-amp electrical circuit may result in erroneous tripping, premature failure of the RCCBs, loss of power to the feather pump system, and reduced controllability of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect two remote controlled circuit breakers (RCCBs) in specific electrical compartments to identify their part numbers. Replace the RCCBs with new ones having a different part number if necessary to ensure compliance with the 50-amp circuit requirements.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Saab Model SAAB 340B series airplanes equipped with Hamilton Sundstrand propellers.
AI-generated summary from the source AD text. Verify against the official source before acting.