AD 2004-06-08
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | DHC-8-401 and -402 | Airworthiness Directives; Bombardier Model DHC-8-401 and -402 Airplanes |
Unsafe Condition
A short circuit on the aileron/rudder trim control panel could cause a runaway condition of the rudder trim actuator, resulting in reduced controllability of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the wiring of the rudder trim switch. Inspect all wiring on the back of the aileron/rudder trim control panel for chafing. Replace any chafed wiring with new wiring.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model DHC-8-401 and -402 airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain