AD 2004-01-15

Recurring final rule
Data completeness: 70%

Airworthiness Directives; McDonnell Douglas Model 717-200 Airplanes

AD Number
2004-01-15
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 2003-NM-55-AD
FR Citation
69 FR 1659

Applicability

TypeManufacturerModelDetails
aircraft McDonnell Douglas 717-200 Airworthiness Directives; McDonnell Douglas Model 717-200 Airplanes

Unsafe Condition

Failure of the electric motor of the auxiliary hydraulic pump and associated wiring, which could result in fire at the auxiliary hydraulic pump and consequent damage to adjacent electrical equipment and/or structure.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the electric motor of the auxiliary hydraulic pump for electrical resistance, continuity, mechanical rotation, and associated wiring resistance/voltage. Perform corrective actions if necessary.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 50 flight hours after the effective date of the AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

McDonnell Douglas Model 717-200 airplanes with the specified auxiliary hydraulic pump system.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain