AD 2002-23-17
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | McDonnell Douglas | MD-90-30 | Airworthiness Directives; McDonnell Douglas Model MD-90-30 Airplanes |
Unsafe Condition
Electrical arcing and/or heat-damaged wiring due to improper wire installations or maintenance practices, which could result in fire and smoke in various areas of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 5 years after the effective date, perform one-time detailed inspections of all electrical wiring installations in specified areas of the airplane according to Boeing Service Bulletins MD90-24-066 through MD90-24-072, excluding Appendices and Evaluation Forms. If any discrepancy is detected, accomplish the applicable corrective action(s) before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 5 years after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All McDonnell Douglas Model MD-90-30 airplanes, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain