AD 2002-16-16
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dornier | Model 328-100 and -300 Series | Airworthiness Directives; Dornier Model 328-100 and -300 Series Airplanes |
Unsafe Condition
Failure of the actuating cartridge on the auxiliary power unit (APU) fire extinguisher, which could result in the inability to extinguish an APU fire in-flight and consequent reduced structural integrity of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the identification plate on the fire extinguisher bottle of the APU. Replace the existing actuating cartridge with a correct actuating cartridge, if necessary. Remove the fire extinguisher bottle equipped with the actuating cartridge from the APU and reinstall it with the correct actuating cartridge.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Model 328-100 and -300 series airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.