AD 2002-03-12
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier Inc. | DHC-8-400 | Airworthiness Directives; Bombardier Model DHC-8-400 Series Airplanes |
| aircraft | Bombardier Inc. | DHC-8-401 | Airworthiness Directives; Bombardier Model DHC-8-400 Series Airplanes |
| aircraft | Bombardier Inc. | DHC-8-402 | Airworthiness Directives; Bombardier Model DHC-8-400 Series Airplanes |
Unsafe Condition
Inadequate clearance between the fuel tank vent lines and the adjacent rib structures of the wings, or failure of certain temporary, reworked fuel probes in the center fuel tanks in the wings, could compromise the airplane's lightning protection system, possibly resulting in a fire or explosion if the airplane were hit by lightning.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the clearance of the fuel tank vent lines to the left and right wing fuel tanks. Replace three existing fuel probes from the center fuel tank on the left and right wings with new production fuel probes, where applicable.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Not specified in the provided text.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model DHC-8-400 series airplanes, as specified in the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
This amendment adopts a new airworthiness directive (AD), applicable to certain Bombardier Model DHC-8-400 series airplanes, that requires a modification and a replacement affecting the fuel tanks in the wings. All affected airplanes require modification of the clearance of the fuel tank vent lines to the left and the right wing fuel tanks. Some affected airplanes also require replacement of three existing fuel probes from the center fuel tank on the left and right wings with new production fuel probes. This action is prompted by mandatory continuing airworthiness information from a foreign airworthiness authority. The actions specified by this AD are necessary to prevent inadequate clearance between the fuel tank vent lines and the adjacent rib structures of the wings or failure of certain temporary, reworked fuel probes in the center fuel tanks in the wings. Either condition could compromise the airplane's lightning protection system, possibly resulting in a fire or explosion if the airplane were hit by lightning. This action is intended to address the identified unsafe condition.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 67, Number 34 (Wednesday, February 20, 2002)]
[Rules and Regulations]
[Pages 7593-7594]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 02-3586]
[[Page 7593]]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. 2001-NM-140-AD; Amendment 39-12653; AD 2002-03-12]
RIN 2120-AA64
Airworthiness Directives; Bombardier Model DHC-8-400 Series
Airplanes
AGENCY: Federal Aviation Administration, DOT.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: This amendment adopts a new airworthiness directive (AD),
applicable to certain Bombardier Model DHC-8-400 series airplanes, that
requires a modification and a replacement affecting the fuel tanks in
the wings. All affected airplanes require modification of the clearance
of the fuel tank vent lines to the left and the right wing fuel tanks.
Some affected airplanes also require replacement of three existing fuel
probes from the center fuel tank on the left and right wings with new
production fuel probes. This action is prompted by mandatory continuing
airworthiness information from a foreign airworthiness authority. The
actions specified by this AD are necessary to prevent inadequate
clearance between the fuel tank vent lines and the adjacent rib
structures of the wings or failure of certain temporary, reworked fuel
probes in the center fuel tanks in the wings. Either condition could
compromise the airplane's lightning protection system, possibly
resulting in a fire or explosion if the airplane were hit by lightning.
This action is intended to address the identified unsafe condition.
DATES: Effective March 27, 2002.
The incorporation by reference of certain publications listed in
the regulations is approved by the Director of the Federal Register as
of March 27, 2002.
ADDRESSES: The service information referenced in this AD may be
obtained from Bombardier, Inc., Bombardier Regional Aircraft Division,
123 Garratt Boulevard, Downsview, Ontario M3K 1Y5, Canada. This
information may be examined at the Federal Aviation Administration
(FAA), Transport Airplane Directorate, Rules Docket, 1601 Lind Avenue,
SW., Renton, Washington; or at the FAA, New York Aircraft Certification
Office, 10 Fifth Street, Third Floor, Valley Stream, New York; or at
the Office of the Federal Register, 800 North Capitol Street, NW.,
suite 700, Washington, DC.
FOR FURTHER INFORMATION CONTACT: Richard Fiesel, Aerospace Engineer,
ANE-171, FAA, New York Aircraft Certification Office, 10 Fifth Street,
Third Floor, Valley Stream, New York 11581; telephone (516) 256-7504;
fax (516) 568-2716.
SUPPLEMENTARY INFORMATION: A proposal to amend part 39 of the Federal
Aviation Regulations (14 CFR part 39) to include an airworthiness
directive (AD) that is applicable to certain Bombardier Model DHC-8-400
series airplanes was published in the Federal Register on November 19,
2001 (66 FR 57905). That action proposed to require two actions--a
modification and a replacement--affecting the fuel tanks in the wings.
All affected airplanes would require modification of the clearance of
the fuel tank vent lines to the left and the right wing fuel tanks.
Some affected airplanes would also require replacement of three
existing fuel probes from the center fuel tank on the left and right
wings with new production fuel probes.
Comments
Interested persons have been afforded an opportunity to participate
in the making of this amendment. No comments were submitted in response
to the proposal or the FAA's determination of the cost to the public.
Explanation of Change to Final Rule
Since the issuance of the notice of proposed rulemaking (NPRM), the
FAA has found that paragraph (b) of the NPRM needs to be clarified.
That paragraph requires that replacement of the existing fuel probes 1,
2, and 5 with new production fuel probes be accomplished ``Prior to the
accumulation of 4,000 flight hours * * *'' It was our intent that the
replacement be accomplished prior to the accumulation of 4,000
``total'' flight hours. Therefore, we have revised paragraph (b) of the
final rule to specify total flight hours.
Conclusion
After careful review of the available data, the FAA has determined
that air safety and the public interest require the adoption of the
rule with the change described previously. The FAA has determined that
this change will neither increase the economic burden on any operator
nor increase the scope of the AD.
Cost Impact
There are approximately 32 airplanes of the affected design in the
worldwide fleet. The FAA estimates that 15 airplanes of U.S. registry
will be affected by this AD.
Thirteen airplanes of U.S. registry will be affected by the
required modification of the clearance of the fuel tank vent line. It
will take approximately 12 work hours to accomplish the required
modification, at an average labor rate of $60 per work hour. Required
parts will cost approximately $440 per airplane. Based on these
figures, the cost impact of the required modification on U.S. operators
is estimated to be $15,080, or $1,160 per airplane.
Seven airplanes of U.S. registry will be affected by the required
replacement of the numbers 1, 2, and 5 fuel probes. It will take
approximately 2 work hours to accomplish the required replacement, at
an average labor rate of $60 per work hour. Required parts will be
provided by the manufacturer at no cost to the operators. Based on
these figures, the cost impact of the required replacement on U.S.
operators is estimated to be $840, or $120 per airplane.
The cost impact figures discussed above are based on assumptions
that no operator has yet accomplished any of the requirements of this
AD action, and that no operator would accomplish those actions in the
future if this AD were not adopted. The cost impact figures discussed
in AD rulemaking actions represent only the time necessary to perform
the specific actions actually required by the AD. These figures
typically do not include incidental costs, such as the time required to
gain access and close up, planning time, or time necessitated by other
administrative actions.
Regulatory Impact
The regulations adopted herein will not have a substantial direct
effect on the States, on the relationship between the national
Government and the States, or on the distribution of power and
responsibilities among the various levels of government. Therefore, it
is determined that this final rule does not have federalism
implications under Executive Order 13132.
For the reasons discussed above, I certify that this action (1) is
not a ``significant regulatory action'' under Executive Order 12866;
(2) is not a ``significant rule'' under DOT Regulatory Policies and
Procedures (44 FR 11034, February 26, 1979); and (3) will not have a
significant economic impact, positive or negative, on a substantial
number of small entities under the criteria of the Regulatory
Flexibility Act. A final evaluation has been prepared for this action
and it is contained in the Rules Docket. A copy of it may be obtained
from the Rules Docket at the location provided under the caption
ADDRESSES.
[[Page 7594]]
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, pursuant to the authority delegated to me by the
Administrator, the Federal Aviation Administration amends part 39 of
the Federal Aviation Regulations (14 CFR part 39) as follows:
PART 39--AIRWORTHINESS DIRECTIVES
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
2. Section 39.13 is amended by adding the following new
airworthiness directive:
2002-03-12 Bombardier, Inc. (Formerly de Havilland, Inc.): Amendment
39-12653. Docket 2001-NM-140-AD.
Applicability: Model DHC-8-400 series airplanes; certificated in
any category; serial numbers 4005, 4006, 4008 through 4010
inclusive, 4012 through 4015 inclusive, and 4018 through 4040
inclusive.
Note 1: This AD applies to each airplane identified in the
preceding applicability provision, regardless of whether it has been
modified, altered, or repaired in the area subject to the
requirements of this AD. For airplanes that have been modified,
altered, or repaired so that the performance of the requirements of
this AD is affected, the owner/operator must request approval for an
alternative method of compliance in accordance with paragraph (c) of
this AD. The request should include an assessment of the effect of
the modification, alteration, or repair on the unsafe condition
addressed by this AD; and, if the unsafe condition has not been
eliminated, the request should include specific proposed actions to
address it.
Compliance: Required as indicated, unless accomplished
previously.
To prevent inadequate clearance between the fuel tank vent lines
and the adjacent rib structures of the wings or failure of certain
temporary, reworked fuel probes in the center fuel tanks in the
wings, either of which could compromise the airplane's lightning
protection system, possibly resulting in a fire or explosion if the
airplane were hit by lightning, accomplish the following:
Modification of Clearance of Fuel Tank Vent Lines
(a) For airplanes having serial numbers 4005, 4006, 4008 through
4010 inclusive, 4012 through 4015 inclusive, and 4018 through 4040
inclusive: Within 120 days after the effective date of this AD,
modify the clearance of the fuel tank vent lines to the left and the
right wing fuel tanks by wrapping 1 piece of Teflon tube around the
vent line at each of 10 stations (2 pieces at station 191.200) and
securing it with a clamping band (2 clamping bands at station
191.200), in accordance with the Accomplishment Instructions
(including Table 1) and Figure 1 of Bombardier Alert Service
Bulletin A84-28-02, dated February 7, 2001.
Replacement of Fuel Probes Numbers 1, 2, and 5
(b) For airplanes having serial numbers 4006, 4008, 4012 through
4015 inclusive, and 4018 through 4027 inclusive: Prior to the
accumulation of 4,000 total flight hours or within 120 days after
the effective date of this AD, whichever occurs later: Replace
existing fuel probes numbers 1, 2, and 5 from the center fuel tank
on the left and the right wings with new production fuel probes, in
accordance with Bombardier Service Bulletin 84-28-01, Revision
``A,'' dated February 8, 2001.
Alternative Methods of Compliance
(c) An alternative method of compliance or adjustment of the
compliance time that provides an acceptable level of safety may be
used if approved by the Manager, New York Aircraft Certification
Office (ACO), FAA. Operators shall submit their requests through an
appropriate FAA Principal Maintenance Inspector, who may add
comments and then send it to the Manager, New York ACO.
Note 2: Information concerning the existence of approved
alternative methods of compliance with this AD, if any, may be
obtained from the New York ACO.
Special Flight Permits
(d) Special flight permits may be issued in accordance with
sections 21.197 and 21.199 of the Federal Aviation Regulations (14
CFR 21.197 and 21.199) to operate the airplane to a location where
the requirements of this AD can be accomplished.
Incorporation by Reference
(e) The actions shall be done in accordance with Bombardier
Alert Service Bulletin A84-28-02, dated February 7, 2001; and
Bombardier Service Bulletin 84-28-01, Revision ``A,'' dated February
8, 2001; as applicable. This incorporation by reference was approved
by the Director of the Federal Register in accordance with 5 U.S.C.
552(a) and 1 CFR part 51. Copies may be obtained from Bombardier,
Inc., Bombardier Regional Aircraft Division, 123 Garratt Boulevard,
Downsview, Ontario M3K 1Y5, Canada. Copies may be inspected at the
FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton,
Washington; or at the FAA, New York Aircraft Certification Office,
10 Fifth Street, Third Floor, Valley Stream, New York; or at the
Office of the Federal Register, 800 North Capitol Street, NW., suite
700, Washington, DC.
Note 3: The subject of this AD is addressed in Canadian
airworthiness directive CF-2001-14, dated March 21, 2001.
Effective Date
(f) This amendment becomes effective on March 27, 2002.
Issued in Renton, Washington, on February 7, 2002.
Vi L. Lipski,
Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 02-3586 Filed 2-19-02; 8:45 am]
BILLING CODE 4910-13-U