AD 2001-13-10
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Saab | SAAB 2000 | Airworthiness Directives; Saab Model SAAB 2000 Series Airplanes |
Unsafe Condition
Faulty activation of the emergency pitch trim actuator (EPTA), which could cause damage to the elevator front spar, resulting in reduced structural integrity of the elevator and a non-functioning emergency pitch trim system (EPTS).
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 400 flight hours from the effective date, perform a functional test of the EPTS according to Saab Service Bulletin 2000-27-046. If the left or right EPTA is not working as per the test, before further flight, check the wiring and perform all applicable corrective actions as per paragraph 2.C. of the same service bulletin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 400 flight hours from the effective date
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Saab Model SAAB 2000 series airplanes, certificated in any category, serial numbers -004 through -063, inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain