AD 2000-23-03

final rule

Airworthiness Directives; Fokker Model F.28 Mark 1000, 2000, 3000, and 4000 Series Airplanes

AD Number
2000-23-03
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 2000-NM-293-AD
FR Citation
65 FR 68882

Applicability

TypeManufacturerModelDetails
aircraft Fokker Various Airworthiness Directives; Fokker Model F.28 Mark 1000, 2000, 3000, and 4000 Series Airplanes

Unsafe Condition

Improper rigging of the liftdumper micro switches could result in inadvertent extension of the liftdumpers during takeoff roll.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a one-time general visual inspection for proper rigging of the liftdumper micro switches installed in the left- and right-hand sides of the pedestal; conduct a functional check of the micro switches; and re-rig the cam, if necessary, as specified in Fokker Service Bulletin F28/27-186, including Manual Change Notification MCNM F28-020.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 2 months after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

All Fokker Model F.28 Mark 1000, 2000, 3000, and 4000 series airplanes, certificated in any category.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

This amendment adopts a new airworthiness directive (AD), applicable to all Fokker Model F.28 Mark 1000, 2000, 3000, and 4000 series airplanes, that requires a one-time general visual inspection for proper rigging of the liftdumper micro switches installed in the left- and right-hand sides of the pedestal; a functional check of the micro switches; and re-rigging the cam, if necessary. The actions specified by this AD are intended to detect and correct improper rigging of the liftdumper micro switches, which could result in inadvertent extension of the liftdumpers during takeoff roll. This action is intended to address the identified unsafe condition.

Document Text

Show stored source text (verify against official source)
[Federal Register Volume 65, Number 221 (Wednesday, November 15, 2000)]
[Rules and Regulations]
[Pages 68882-68884]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 00-28962]


-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. 2000-NM-293-AD; Amendment 39-11973; AD 2000-23-03]
RIN 2120-AA64


Airworthiness Directives; Fokker Model F.28 Mark 1000, 2000, 
3000, and 4000 Series Airplanes

AGENCY: Federal Aviation Administration, DOT.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: This amendment adopts a new airworthiness directive (AD), 
applicable to all Fokker Model F.28 Mark 1000, 2000, 3000, and 4000 
series airplanes, that requires a one-time general visual inspection 
for proper rigging of the liftdumper micro switches installed in the 
left- and right-hand sides of the pedestal; a functional check of the 
micro switches; and re-rigging the cam, if necessary. The actions 
specified by this AD are intended to detect and correct improper 
rigging of the liftdumper micro switches, which could result in 
inadvertent extension of the liftdumpers during takeoff roll. This 
action is intended to address the identified unsafe condition.

DATES: Effective December 20, 2000.
    The incorporation by reference of certain publications listed in 
the regulations is approved by the Director of the Federal Register as 
of December 20, 2000.

ADDRESSES: The service information referenced in this AD may be 
obtained from Fokker Services B.V., P.O. Box 231, 2150 AE Nieuw-Vennep, 
the Netherlands. This information may be examined at the Federal 
Aviation Administration (FAA), Transport Airplane Directorate, Rules 
Docket, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of 
the Federal Register, 800 North Capitol Street, NW., suite 700, 
Washington, DC.

[[Page 68883]]


FOR FURTHER INFORMATION CONTACT: Norman B. Martenson, Manager, 
International Branch, ANM-116, FAA, Transport Airplane Directorate, 
1601 Lind Avenue, SW., Renton, Washington 98055-4056; telephone (425) 
227-2110; fax (425) 227-1149.

SUPPLEMENTARY INFORMATION: A proposal to amend part 39 of the Federal 
Aviation Regulations (14 CFR part 39) to include an airworthiness 
directive (AD) that is applicable to all Fokker Model F.28 Mark 1000, 
2000, 3000, and 4000 series airplanes was published in the Federal 
Register on September 19, 2000 (65 FR 56509). That action proposed to 
require a one-time general visual inspection for proper rigging of the 
liftdumper micro switches installed in the left- and right-hand sides 
of the pedestal; a functional check of the micro switches; and re-
rigging the cam, if necessary.

Comments

    Interested persons have been afforded an opportunity to participate 
in the making of this amendment. No comments were submitted in response 
to the proposal or the FAA's determination of the cost to the public.

Conclusion

    The FAA has determined that air safety and the public interest 
require the adoption of the rule as proposed.

Cost Impact

    The FAA estimates that 23 airplanes of U.S. registry will be 
affected by this AD, that it will take approximately 4 work hours per 
airplane to accomplish the required actions, and that the average labor 
rate is $60 per work hour. Based on these figures, the cost impact of 
the AD on U.S. operators is estimated to be $5,520, or $240 per 
airplane.
    The cost impact figure discussed above is based on assumptions that 
no operator has yet accomplished any of the requirements of this AD 
action, and that no operator would accomplish those actions in the 
future if this AD were not adopted. The cost impact figures discussed 
in AD rulemaking actions represent only the time necessary to perform 
the specific actions actually required by the AD. These figures 
typically do not include incidental costs, such as the time required to 
gain access and close up, planning time, or time necessitated by other 
administrative actions.

Regulatory Impact

    The regulations adopted herein will not have a substantial direct 
effect on the States, on the relationship between the national 
Government and the States, or on the distribution of power and 
responsibilities among the various levels of government. Therefore, it 
is determined that this final rule does not have federalism 
implications under Executive Order 13132.
    For the reasons discussed above, I certify that this action (1) is 
not a ``significant regulatory action'' under Executive Order 12866; 
(2) is not a ``significant rule'' under DOT Regulatory Policies and 
Procedures (44 FR 11034, February 26, 1979); and (3) will not have a 
significant economic impact, positive or negative, on a substantial 
number of small entities under the criteria of the Regulatory 
Flexibility Act. A final evaluation has been prepared for this action 
and it is contained in the Rules Docket. A copy of it may be obtained 
from the Rules Docket at the location provided under the caption 
ADDRESSES.

List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Incorporation by 
reference, Safety.

Adoption of the Amendment

    Accordingly, pursuant to the authority delegated to me by the 
Administrator, the Federal Aviation Administration amends part 39 of 
the Federal Aviation Regulations (14 CFR part 39) as follows:

PART 39--AIRWORTHINESS DIRECTIVES

    1. The authority citation for part 39 continues to read as follows:

    Authority: 49 U.S.C. 106(g), 40113, 44701.


Sec. 39.13  [Amended]

    2. Section 39.13 is amended by adding the following new 
airworthiness directive:

2000-23-03  Fokker Services B.V.: Amendment 39-11973. Docket 2000-
NM-293-AD.

    Applicability: All Model F.28 Mark 1000, 2000, 3000, and 4000 
series airplanes, certificated in any category.

    Note 1: This AD applies to each airplane identified in the 
preceding applicability provision, regardless of whether it has been 
modified, altered, or repaired in the area subject to the 
requirements of this AD. For airplanes that have been modified, 
altered, or repaired so that the performance of the requirements of 
this AD is affected, the owner/operator must request approval for an 
alternative method of compliance in accordance with paragraph (b) of 
this AD. The request should include an assessment of the effect of 
the modification, alteration, or repair on the unsafe condition 
addressed by this AD; and, if the unsafe condition has not been 
eliminated, the request should include specific proposed actions to 
address it.

    Compliance: Required as indicated, unless accomplished 
previously.
    To detect and correct improper rigging of the liftdumper micro 
switches, which could result in inadvertent extension of the 
liftdumpers during takeoff roll, accomplish the following:

Inspection and Functional Check

    (a) Within 2 months after the effective date of this AD: Perform 
a one-time general visual inspection for proper rigging of the 
liftdumper micro switches installed in the left- and right-hand 
sides of the pedestal; and a functional check of the micro switches; 
as specified in Fokker Service Bulletin F28/27-186, including Manual 
Change Notification MCNM F28-020, dated May 8, 2000. Perform the 
inspection and the check in accordance with the Accomplishment 
Instructions of the service bulletin. If the micro switches are not 
rigged within the specifications provided in the service bulletin, 
prior to further flight, re-rig the cam in accordance with the 
service bulletin.

    Note 2: For the purposes of this AD, a general visual inspection 
is defined as: ``A visual examination of an interior or exterior 
area, installation, or assembly to detect obvious damage, failure, 
or irregularity. This level of inspection is made under normally 
available lighting conditions such as daylight, hangar lighting, 
flashlight, or drop-light, and may require removal or opening of 
access panels or doors. Stands, ladders, or platforms may be 
required to gain proximity to the area being checked.''

Alternative Methods of Compliance

    (b) An alternative method of compliance or adjustment of the 
compliance time that provides an acceptable level of safety may be 
used if approved by the Manager, International Branch, ANM-116, FAA, 
Transport Airplane Directorate. Operators shall submit their 
requests through an appropriate FAA Principal Maintenance Inspector, 
who may add comments and then send it to the Manager, International 
Branch, ANM-116.

    Note 3: Information concerning the existence of approved 
alternative methods of compliance with this AD, if any, may be 
obtained from the International Branch, ANM-116.

Special Flight Permits

    (c) Special flight permits may be issued in accordance with 
sections 21.197 and 21.199 of the Federal Aviation Regulations (14 
CFR 21.197 and 21.199) to operate the airplane to a location where 
the requirements of this AD can be accomplished.

Incorporation by Reference

    (d) The actions shall be done in accordance with Fokker Service 
Bulletin F28/27-186, including Manual Change Notification MCNM F28-
020, dated May 8, 2000. This incorporation by reference was approved 
by the Director of the Federal Register in accordance with 5 U.S.C. 
552(a) and 1 CFR part 51. Copies may be obtained from Fokker 
Services B.V., P.O. Box 231, 2150 AE Nieuw-Vennep, the Netherlands. 
Copies may be inspected at the FAA, Transport Airplane

[[Page 68884]]

Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the 
Office of the Federal Register, 800 North Capitol Street, NW., suite 
700, Washington, DC.

    Note 4: The subject of this AD is addressed in Dutch 
airworthiness directive 2000-073, dated May 31, 2000.

Effective Date

    (e) This amendment becomes effective on December 20, 2000.

    Issued in Renton, Washington, on November 6, 2000.
Donald L. Riggin,
Acting Manager, Transport Airplane Directorate, Aircraft Certification 
Service.
[FR Doc. 00-28962 Filed 11-14-00; 8:45 am]
BILLING CODE 4910-13-P

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.