AD 2000-22-12
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Embraer | EMB-120 | Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model EMB-120 Series Airplanes |
Unsafe Condition
Overheating of the wire between circuit breakers 0304 and 0358, which could result in smoke emissions in the cockpit.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the existing wire between circuit breakers 0304 and 0358 with a wire coded W200-1063-12, in accordance with EMBRAER Service Bulletin 120-30-0028.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
At the next scheduled maintenance inspection (``A''-check), but no later than 400 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
EMBRAER Model EMB-120 series airplanes, serial numbers 120003, 120004, 120006 through 120308 inclusive, 120310, 120312 through 120314 inclusive, 120316 through 120323 inclusive, and 120325 through 120330 inclusive; certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.