AD 2000-03-15
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | McDonnell Douglas | MD-11 and MD-11F | Airworthiness Directives; McDonnell Douglas Model MD-11 and MD-11F Series Airplanes |
Unsafe Condition
Electrical arcing occurred at a terminal strip in the main cabin, caused by power feeder cable terminal lugs grounding against terminal strip support brackets.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace existing terminal strips and supports above the main cabin area. Install spacers between terminal strips and mounting brackets in the avionics compartment, as applicable.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
McDonnell Douglas Model MD-11 and MD-11F series airplanes, as specified in the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain