AD 2000-01-02

final rule
Data completeness: 70%

Airworthiness Directives; Raytheon Model BAe.125 Series 1000A and 1000B Airplanes and Model Hawker 1000 Series Airplanes

AD Number
2000-01-02
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 99-NM-80-AD
FR Citation
65 FR 1538

Applicability

TypeManufacturerModelDetails
aircraft Raytheon BAe Airworthiness Directives; Raytheon Model BAe.125 Series 1000A and 1000B Airplanes and Model Hawker 1000 Series Airplanes

Unsafe Condition

The turbine air discharge duct may disconnect from the cold air unit (CAU) or water separator due to insufficient bead height on the ends of the duct.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the integrity of the duct connection on both ends of the turbine air discharge duct. Measure the bead height on the ends of the turbine air discharge duct. Take corrective actions if necessary.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Raytheon Model BAe.125 Series 1000A and 1000B airplanes and Model Hawker 1000 Series airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗